File No.: TB-9627 Date: July 16, 1996
Model: FL-2100/B Serial No. Range Complaint unit

Problem: Oscillation causes burned components when using Svetlana 572B tubes.

Expected Results of Modification: Improve Circuit.

Component Value Changes: Main Unit
Part Location No. From To New Part No.
       

Added/Deleted Component: Main Unit
Part Location No. Device Type Added/Deleted New Part No.
Chassis      
  10D10 A G2090002
  1000uF     25WV A K40149005
  22 ohm     1W A J20306220

Procedure
See Diagrams

Bias Level Adjustment   After the modification is completed, you must adjust the bias level. With the function switch in the operate position, activate the amp relay with no RF drive applied. Adjust R4 for an idling current of 0.03 amps on the IP meter.
DO NOT adjust to 0.090 as in manual.



RF Parts Company offers necessary modification components in their kit.
Modification Kit Part Number: FL2100-1Kit     •      $2.50 ea.